Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 176
Filtrar
1.
J Endod ; 2024 Apr 18.
Artículo en Inglés | MEDLINE | ID: mdl-38642733

RESUMEN

INTRODUCTION: The purpose of this study was to evaluate the effect of side flattening of cutting flutes on the cyclic resistance and torsional resistance of nickel-titanium files. METHODS: Both novel flattened Platinum V.EU (PL) and standard nonflattened CC Premium V.EU (CC) rotaries were tested. For cyclic fatigue tests, all the files were rotated in an artificial root canal with a curvature of 45° and a radius of 6.06 mm at 300 rpm (n = 15 in each group). The number of cycles to failure (NCF) was calculated. For torsional tests, the files were rotated at 2 rpm clockwise until fracture occurred. The maximum torque value at fracture was measured and the toughness and distortion angle were computed. Subsequently, 5 fragments were randomly selected in each experiment, the cross-section and longitudinal direction of the fragments were photographed using a scanning electron microscope. An unpaired t-test was performed at a significance level of 95%. RESULTS: There was a statistically significant difference in NCF between CC and PL (P < .05). CC showed higher NCF than PL. There was no statistically significant difference between CC and PL with regards to the parameters related to torsional resistance (distortion angle, ultimate strength, and toughness) (P > .05). CONCLUSION: Within the limitations of this study, side flattening of the file did not improve cyclic resistance or torsional resistance of the files. As side flattening may reduce a file's cyclic resistance, such files should be used with caution in clinical practice.

2.
Dent J (Basel) ; 12(4)2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38667997

RESUMEN

This study aimed to review the considerations for choosing a suitable sealer according to various endodontic scenarios. An electronic search of PubMed, Scopus, and the Web of Science was undertaken for the keywords of 'sealer choosing', 'appropriate sealer', 'suitable sealer', 'sealer for clinical scenario', and 'sealer for clinical situations'. However, the literature review revealed a lack of studies with practical clinical recommendations regarding the choice of appropriate endodontic root canal sealers for particular clinical situations of root canal treatment. Therefore, a narrative review was undertaken under the basis of the characteristics of an epoxy resin-based sealer (ERS) versus a calcium silicate-based sealer (CSS). Based on the evidence found through the review, the choice of an appropriate sealer in a variety of clinical scenarios was proposed. An ERS is recommended for one-visit non-vital cases, teeth with periodontal involvement, cracked teeth, and internal root resorption without root perforation. A CSS is recommended for vital or non-vital cases in multiple visits, teeth with internal root resorption with perforation or internal approach for external cervical resorption, teeth with open apices, and teeth with iatrogenic aberrations.

3.
Aust Endod J ; 2024 Mar 25.
Artículo en Inglés | MEDLINE | ID: mdl-38528685

RESUMEN

The aim of this study was to assess the effect of ibuprofen sustained release (SR) oral premedication on the efficacy of buccal infiltration (BI) with intraoperative and postoperative pain after single-visit root canal treatment. Sixty patients diagnosed with symptomatic irreversible pulpitis and apical periodontitis in mandibular molar were divided into two groups. Group SR received ibuprofen SR 800 mg and group PL received placebo capsule 1 h before 3.6 mL articaine BI injection. Pain was recorded using a modified visual analogue scale and postoperatively at intervals 6, 24 and 48 h. Group SR showed a significantly higher anaesthetic success rate (73.3%) compared to group PL (46.7%) (p < 0.05). Intraoperative and postoperative pain was significantly higher in group PL compared to group SR (p < 0.05). Premedication of ibuprofen SR improved the efficacy of primary BI in mandibular molars with symptomatic irreversible pulpitis and decreased postoperative pain at 6 and 48 h.

4.
J Endod ; 50(4): 520-526, 2024 Apr.
Artículo en Inglés | MEDLINE | ID: mdl-38311116

RESUMEN

INTRODUCTION: This study aimed to evaluate the effects from the memory-triple (MT) heat treatment on the fatigue resistance of the Reciproc by comparison with the file systems of same geometry. METHODS: Reciproc files subjected to MT heat treatment technology were designated as Group RMT and were compared with the original Reciproc (Group REC) and Reciproc Blue (Group REB). Each NiTi file from 3 groups (n = 15) was operated reciprocally with a repetitive up-and-down movement in the curved canal with 4 mm of pecking distance inside of the simulated canal at body temperature. When each file fractured, the time until fracture was recorded. The length of the fractured fragment was measured. Fractured fragments were observed under scanning electron microscope (SEM) to evaluate the topographic features of the surface. Differential scanning calorimetry (DSC) analysis was performed to estimate phase transformation temperatures. One-way analysis of variance and Duncan post hoc comparison were applied to compare among the groups at a significance level of 95%. RESULTS: RMT showed significantly higher fracture resistance (P < .05), whereas there was no difference in fatigue resistance between REC and REB. SEM examination showed the files from the 3 groups had similar topographic features. RMT showed a peak of austenite peak (Ap) at a temperature (52°C) higher than body temperature, whereas REC and REB showed Ap at 37 and 32°C, respectively. CONCLUSIONS: Under the condition of this study, the new heat treatment technique of MT technology could enhance the fatigue fracture resistance of the reciprocating files made of M-wire and Blue-wire.


Asunto(s)
Calor , Preparación del Conducto Radicular , Falla de Equipo , Estrés Mecánico , Instrumentos Dentales , Ensayo de Materiales , Diseño de Equipo , Titanio
5.
Dent J (Basel) ; 12(2)2024 Feb 18.
Artículo en Inglés | MEDLINE | ID: mdl-38392245

RESUMEN

This review explores the field of retreatment strategies for cases filled with calcium silicate-based root canal sealers. Since the introduction of calcium silicate-based materials in dentistry, calcium silicate-based root canal sealers have become popular among dentists because of their biocompatibility, bioactivity, and sealing ability. Therefore, effective retreatment strategies are indispensable. This article aims to identify the challenges associated with the removal of calcium silicate-based sealers themselves and removal of gutta-percha with the sealers during retreatment, evaluate current techniques and materials, and provide future directions for research in this field. Regarding the strategies of removal of root canal sealers, calcium silicate-based sealers are still relatively new materials for clinicians compared with traditional sealers such as epoxy- or eugenol-based sealers. First, no clinically established solvents have been reported. Second, calcium silicate-based sealers are currently utilized by clinicians in either the cold sealer-based technique or the warm vertical condensation technique. Third, the setting process of calcium silicate-based sealers generates byproducts, primarily calcium hydroxide and secondarily hydroxyapatite, that could interact with dentine. Lastly, there is a lack of clinical studies evaluating the efficacy of retreatment protocols for teeth filled with calcium silicate-based sealers. Therefore, it is important to investigate the chemo-mechanical properties of calcium silicate-based sealers themselves and their reactions to solvents and/or mechanical instruments and identify the interfacial properties of calcium silicate-based sealers with respect to dentine and gutta-percha. In addition, researchers in the clinical field need to actively gather and report data on retreatments of teeth filled with calcium silicate-based sealers.

6.
J Endod ; 50(2): 213-219, 2024 Feb.
Artículo en Inglés | MEDLINE | ID: mdl-37924940

RESUMEN

INTRODUCTION: The aim of this study was to evaluate the torsional resistance, cyclic fatigue resistance, and bending stiffness of nickel-titanium (NiTi) file systems with different heat treatments and cross-sectional designs. METHODS: WaveOne Primary treated with memory-triple (MT) heat treatment (WOMT) was compared with WaveOne Primary (WO) and WaveOne Gold Primary (WOG). Torsional resistance test was performed using a customized device, and the distortion angle, ultimate strength, and toughness were evaluated. For cyclic fatigue resistance test, the instruments were reciprocated with continuous 4 mm up-and-down movement until fracture in a customized device, and the time to fracture was compared. Fracture surfaces of each group were examined under the scanning electron microscope. Bending stiffness was measured using a custom-made device. The results were analyzed using one-way analysis of variance and the Tukey's post hoc comparison at a significance level of 95%. RESULTS: WOMT showed higher ultimate strength and toughness than the other systems (P < .05). WOMT also showed highest cyclic fatigue resistance among the tested groups (P < .05). WO had the highest bending stiffness than others, whereas WOMT had a larger residual angle than others (P < .05). CONCLUSIONS: This new MT heat treatment technique makes NiTi file more flexible and improves its mechanical properties. In addition, the effect of heat treatment on flexibility was found to be more significant than that of the cross-sectional area.


Asunto(s)
Aleaciones , Calor , Titanio , Níquel , Instrumentos Dentales , Diseño de Equipo , Preparación del Conducto Radicular , Estrés Mecánico , Ensayo de Materiales , Torsión Mecánica
7.
Artículo en Inglés | MEDLINE | ID: mdl-37886428

RESUMEN

The aim of this study is to optimize the performance conditions used for maximum anti-inflammatory activity and to clarify in vitroanti-inflammatory properties of fermented C. tricuspidata fruit. Based on the single-factor experiment and Box-Behnken design, the optimized fermentation conditions of C. tricuspidata fruit for maximum anti-inflammatory activity were 3.8 d fermentation period, 8.4% (v/w) inoculation concentration, and 29.2°C fermentation temperature. Under optimal conditions, anti-inflammatory activity-based nitric oxide of fermented C. tricuspidata fruit reached 93.9%. Moreover, this study provides a theoretical basis and experimental data containing ß-hexosaminidase and reactive oxygen species for the medical use and industrialization of C. tricuspidata fruit fermentation. Interestingly, the results of GC-MS analysis confirmed that fermented C. tricuspidata fruits detect volatile components different from unfermented C. tricuspidata fruits. We suggested that this volatile component may have been involved in the anti-inflammatory reaction, but scientific verification of this is needed later. Therefore, an in-depth study of volatile components detected from fermented C. tricuspidata fruits will need to be conducted later.

8.
J Dent Sci ; 18(4): 1561-1566, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37799868

RESUMEN

Background/purpose: Clinical test results may have lower reliability due to the varying range of test stimulation or patient subjectiveness. This study aimed to verify a reliable clinical test method by comparing pain intensity levels of a tooth at rest, during function, and after the clinical tests of percussion and chewing. Materials and methods: A total of 36 asymptomatic necrotic teeth that required root canal treatment, one in each patient, were included. All treatment procedures were performed in a single visit by an experienced endodontist. Patients were asked to mark their pain levels on a vertical visual analog scale (VAS) while the relevant tooth was at rest and during function 24 h after the treatment. In addition, patients marked their pain levels after the clinical tests of percussion and chewing. Finally, the pain levels were compared using Pearson's correlation for the reliability of the test methods at a significance level of 95%. Results: The postoperative pain levels measured during the clinical tests and functions were significantly higher than the pain levels at rest (P < 0.05). The pain levels after percussion tests were significantly higher than that during the function and chewing tests (P < 0.05). Pain intensity during the function was simulated with a higher correlation when using the chewing strip method rather than the percussion method. Conclusion: The bite test using the chewing strips as a pain intensity assessment can mimic the actual postoperative pain experience, whereas the percussion test fails to provide the accuracy of this pain experience.

9.
J Endod ; 49(12): 1706-1712, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37802135

RESUMEN

INTRODUCTION: This study investigated different access cavity designs of mandibular anteriors in terms of their effect on the biomechanical behavior and longevity using finite element analysis (FEA). METHODS: A 3-dimensional model of a mandibular incisor was created for FEA. After validating the intact tooth (IT) model, 4 experimental models were developed (traditional lingual access cavity [TLA], facial access cavity [FAC], incisal access cavity [ICA], and cervical access cavity [CVA]). Cyclic loading was simulated, and the number of cycles until failure (NCF) was compared to the IT model. Stress distribution patterns, maximum von Mises stresses (vMSs), and maximum principal stresses (MPSs) were analyzed mathematically. The safety factor was also calculated and demonstrated. RESULTS: The maximum vMS registered on the IT model was 134.16 MPa. The FCA and the CVA provided the highest NCF (193.7% compared with the IT model) followed by ICA (58.2%) and TLA (21.4%). The vM and MPS analysis revealed that the lingual surface is a primary stress channel, and the presence of an access cavity significantly weakens the tooth structure. Although the maximum vMS registered for the IT model was 134.16 MPa, the maximum vMS was 73.97 MPa for both the FCA and the CVA, 152.27 MPa for the ICA, and 173.63 MPa for the TLA. CONCLUSIONS: The facial and cervical access cavity designs provided considerable reinforcement to the endodontically treated mandibular incisors. With advancements in esthetic restorative materials and endodontic instruments, facial access design could emerge as the new standard for access cavity preparation in mandibular incisors.


Asunto(s)
Materiales Dentales , Incisivo , Estrés Mecánico , Análisis de Elementos Finitos , Mandíbula , Análisis del Estrés Dental
10.
J Endod ; 49(12): 1713-1721, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37734586

RESUMEN

INTRODUCTION: This study aimed to evaluate the chemomechanical properties and biocompatibility of recently introduced premixed putty-type bioactive ceramic cements (PPBCs). METHODS: Including ProRoot MTA (PMTA) as a control, BC RRM fast-set putty (BCPT), Well-Root PT (WRPT), One-Fil PT (OFPT), and Endocem MTA premixed (ECPM) were compared to evaluate setting time, radiopacity, pH change, and microhardness. Biocompatibility on human dental pulp cells was compared using CCK-8 assay. Mineralization potential was evaluated using alkaline phosphatase activity, Alizarin Red S (ARS) staining, and quantitative real-time polymerase chain reaction with odontogenic gene marker. For data analysis, 1-way analysis of variance and Tukey's post hoc test were used at the significance level of 95%. RESULTS: Among the PPBCs, BCPT presented the longest (552 ± 27) setting time (minutes) and others showed significantly shorter time than PMTA (334 ± 22) (P < .05). WRPT (6.20 ± 0.54) and OFPT (5.82 ± 0.50) showed significantly higher radiopacity values (mmAl) and others showed similar value compared with PMTA (P > .05). All PPBCs showed high alkaline pH from fresh materials and tended to increase according to time periods from 30 minutes to 12 hours. ECPM showed the highest value of microhardness (81.62 ± 5.90), WRPT showed similar, and others showed lower than PMTA (P < .05). All PPBCs showed biocompatibility in CCK-8 assay. All PPBCs showed similar or better value compared with PMTA in ALP and ARS staining, and ALP and DSPP marker expression (P < .05). CONCLUSIONS: The PPBCs showed clinically acceptable chemomechanical properties and favorable mineralization potential.


Asunto(s)
Compuestos de Calcio , Materiales de Obturación del Conducto Radicular , Humanos , Compuestos de Calcio/farmacología , Compuestos de Calcio/química , Sincalida , Materiales de Obturación del Conducto Radicular/química , Odontogénesis , Cerámica , Silicatos/farmacología , Silicatos/química , Óxidos/química , Combinación de Medicamentos , Ensayo de Materiales , Compuestos de Aluminio/farmacología , Compuestos de Aluminio/química , Cementos Dentales/farmacología
11.
J Dent Sci ; 18(3): 1042-1046, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37404604

RESUMEN

Background/purpose: Recently introduced calcium silicate-based bioceramic (CSBC) sealers require moisture for setting, thus this study aimed to compare the setting times of epoxy resin-and CSBC sealers under different test conditions. Materials and methods: Four CSBC sealers (CeraSeal, EndoSeal TCS, One-Fil, and Well-Root ST) were compared to an epoxy resin-based sealer (AH Plus). Each sealer was placed in a stainless-steel and gypsum molds on a glass slide. Sealer samples (n = 10 per group) were stored in an incubator at 95% humidity and 37 °C. A Gilmore needle with a total weight of 100 g and a 2.0-mm diameter were carefully placed vertically against the sealer, and the setting time was recorded when the needle no longer formed an indentation on the sealer surface. Statistical analysis was performed using two-way analysis of variance and Tukey parametric tests. The level of significance was set at 95%. Results: The setting time of all sealers in gypsum molds was significantly shorter than that in stainless-steel molds (P < 0.05). While AH Plus showed the longest setting time, EndoSeal TCS, One-Fil, and CeraSeal showed the shortest setting times when using gypsum molds among the five sealer types (P < 0.05). Conclusion: The results of this study indicate that CSBC sealers require moisture for setting; a lack of moisture results in a significant delay in setting time. Because the root canals contain moisture, it is necessary to experiment with the setting time of all types of sealers using gypsum molds to determine the biological condition of root canals.

12.
J Endod ; 49(10): 1337-1343, 2023 Oct.
Artículo en Inglés | MEDLINE | ID: mdl-37517584

RESUMEN

INTRODUCTION: This study investigated the effects from the carious cavity and access from it on the fracture resistance of endodontically treated maxillary premolars using finite element analysis (FEA). METHODS: A maxillary premolar was used to compare 3 types of access cavity related to having a proximal carious defect: caries-driven access (CDA), conservative access that has a mesial component (MCA), as well as traditional access with the same mesial component (MTA). Cyclic loading was simulated on the occlusal surface, and number of cycles until failure (NCF) was compared with the intact tooth model (IT). Mathematical analysis was done to evaluate the stress distribution patterns and calculated maximum von Mises (vM) and maximum principal stresses (MPS), with emphasis on pericervical region as a specific area of interest. RESULTS: Maximum vM registered on the IT was 6.14 MPa. CDA provided the highest NCF with 92.28% of the IT, followed by MCA (84.90%) and MTA (83.79%). The vM and MPS analysis showed that the stress values and patterns are affected more by the proximity of the occlusal load to the tooth/restoration interface. Concerning the pericervical region, maximum vM was registered for IT (4.11 MPa), followed by CDA (4.85 MPa) and then MCA (8.13 MPa) and MTA (8.61 MPa), whereas the MPS analysis revealed that CDA showed the highest magnitude of tensile stresses. CONCLUSIONS: A proximal CDA benefits the mechanical properties of maxillary premolars; however, its impact on the biological aspect should be assessed to provide a ruling for/against it.


Asunto(s)
Caries Dental , Diente no Vital , Humanos , Diente Premolar , Susceptibilidad a Caries Dentarias , Caries Dental/terapia , Modelos Dentales , Análisis de Elementos Finitos , Análisis del Estrés Dental , Estrés Mecánico , Diente no Vital/terapia
13.
Aust Endod J ; 49(3): 675-683, 2023 Dec.
Artículo en Inglés | MEDLINE | ID: mdl-37309727

RESUMEN

This article documents cases of single-visit pulp revascularisation for dens evaginatus and dens invaginatus, without using intracranial medicaments or antibiotics, aiming to provide a potentially applicable protocol for pulp revascularisation procedure in a single-visit. Two patients with chief complaints of pain and swelling visited a dental hospital. Radiographs revealed that the causative teeth had an open apex and periapical radiolucency, and the teeth were diagnosed as pulp necrosis and acute apical abscess or symptomatic apical periodontitis. For both cases, single-visit revascularisation was completed without intracanal medicaments or antibiotics. The patients were periodically recalled to evaluate periapical healing after treatment. The apical lesion healed, and the root dentin thickening was observed. The single-visit pulp revascularisation procedure without using specific intracanal medicaments can produce clinically favourable results for these dental anomalies.


Asunto(s)
Dens in Dente , Absceso Periapical , Humanos , Dens in Dente/terapia , Estudios de Seguimiento , Pulpa Dental , Absceso Periapical/terapia , Necrosis de la Pulpa Dental/terapia , Antibacterianos , Tratamiento del Conducto Radicular/métodos
14.
Antiviral Res ; 216: 105656, 2023 08.
Artículo en Inglés | MEDLINE | ID: mdl-37327877

RESUMEN

The ongoing COVID-19 pandemic caused by SARS-CoV-2 infection has threatened global health. Since the first case of infection was reported in December 2019, SARS-CoV-2 has rapidly spread worldwide and caused millions of deaths. As vaccination is the best way to protect the host from invading pathogens, several vaccines have been developed to prevent the infection of SARS-CoV-2, saving numerous lives thus far. However, SARS-CoV-2 constantly changes its antigens, resulting in escape from vaccine-induced protection, and the longevity of immunity induced by vaccines remains an issue. Additionally, traditional intramuscular COVID-19 vaccines are insufficient at evoking mucosal-specific immune responses. Because the respiratory tract is the primary route of SARS-CoV-2 entry, the need for mucosal vaccines is strong. Using an adenoviral (Ad) vector platform, we generated Ad5-S.Mod, a recombinant COVID-19 vaccine that encodes modified-spike (S) antigen and the genetic adjuvant human CXCL9. Intranasal delivery of Ad5-S.Mod elicited superior airway humoral and T-cell responses over traditional intramuscular vaccines and protected mice from lethal SARS-CoV-2 infection. cDC1 cells were required for the generation of antigen-specific CD8+ T-cell responses and CD8+ tissue-resident memory T-cell development in intranasal Ad5-S.Mod vaccinated mice. Furthermore, we confirmed the efficacy of the intranasal Ad5-S.Mod vaccine in terms of transcriptional changes and identified lung macrophages as a key supporter of maintenance of lung-resident memory T and B cells. Our study demonstrates Ad5-S.Mod has the potential to confer protective immunity against SARS-CoV-2 and that lung macrophages support the maintenance of vaccine-induced tissue-resident memory lymphocytes.


Asunto(s)
Infecciones por Adenoviridae , Vacunas contra el Adenovirus , COVID-19 , Ratones , Humanos , Animales , Adenoviridae/genética , Vacunas contra la COVID-19 , SARS-CoV-2/genética , COVID-19/prevención & control , Inmunidad Mucosa , Glicoproteína de la Espiga del Coronavirus/genética , Pandemias , Adyuvantes Inmunológicos , Anticuerpos Antivirales , Anticuerpos Neutralizantes
15.
J Endod ; 49(7): 871-879, 2023 Jul.
Artículo en Inglés | MEDLINE | ID: mdl-37225037

RESUMEN

INTRODUCTION: The aim of this study was to compare the physicochemical properties and biocompatibility of various calcium silicate-based bioceramic sealers (CSBSs). METHODS: Four recently developed CSBSs, including AH Plus Bioceramic Sealer (AHB), EndoSequence BC Sealer (ESB), TotalFill BC Sealer (TTB), and Bio-C Sealer (BIC), were compared with the epoxy resin-based sealer AH Plus (AHP). Their physical properties, including flow, setting time, radiopacity, dimensional stability, and pH, were evaluated according to the International Organization for Standardization (ISO) 6876. Their cytotoxicity in human periodontal ligament fibroblast (hPDLF) was assessed through the 3-(4,5-dimethylthiazol-2-yl)-2,5-diphenyltetrazolium bromide assay and compared. Additionally, cell attachment to the sealer surface was analyzed using green fluorescent protein and confocal laser scanning microscopy to evaluate cell viability. Data were analyzed using a one-way analysis of variance to determine the difference between groups for categorical variables, followed by Tukey's post hoc test at the significance level of 95%. RESULTS: The flow, setting time, and radiopacity of all tested CSBSs satisfied the ISO 6876/2012 standards. Further, these CSBSs showed shrinkage after immersion in distilled water for 30 days and complied with the ISO 6876/2001 requirements. The pH values of AHB, ESB, TTB, and BIC were greater than 11, whereas AHP had a pH of 6.69 after 4 weeks. CSBS showed excellent biocompatibility compared with that of AHP (P < .05). Confocal laser scanning microscopy showed that alive hPDLFs were attached well to all the tested CSBSs but not to AHP. CONCLUSIONS: CSBSs have similar physical characteristics within the ISO standards and higher biocompatibility than epoxy resin-based sealers.


Asunto(s)
Resinas Epoxi , Materiales de Obturación del Conducto Radicular , Humanos , Resinas Epoxi/farmacología , Resinas Epoxi/química , Materiales de Obturación del Conducto Radicular/farmacología , Materiales de Obturación del Conducto Radicular/química , Cavidad Pulpar , Ensayo de Materiales , Compuestos de Calcio/farmacología , Compuestos de Calcio/química , Silicatos/farmacología , Silicatos/química
16.
Cell Mol Immunol ; 20(5): 525-539, 2023 05.
Artículo en Inglés | MEDLINE | ID: mdl-37029318

RESUMEN

CD4+ T cells play major roles in the adaptive immune system, which requires antigen recognition, costimulation, and cytokines for its elaborate orchestration. Recent studies have provided new insight into the importance of the supramolecular activation cluster (SMAC), which comprises concentric circles and is involved in the amplification of CD4+ T cell activation. However, the underlying mechanism of SMAC formation remains poorly understood. Here, we performed single-cell RNA sequencing of CD4+ T cells left unstimulated and stimulated with anti-CD3 and anti-CD28 antibodies to identify novel proteins involved in their regulation. We found that intraflagellar transport 20 (IFT20), previously known as cilia-forming protein, was upregulated in antibody-stimulated CD4+ T cells compared to unstimulated CD4+ T cells. We also found that IFT20 interacted with tumor susceptibility gene 101 (TSG101), a protein that endocytoses ubiquitinated T-cell receptors. The interaction between IFT20 and TSG101 promoted SMAC formation, which led to amplification of AKT-mTOR signaling. However, IFT20-deficient CD4+ T cells showed SMAC malformation, resulting in reduced CD4+ T cell proliferation, aerobic glycolysis, and cellular respiration. Finally, mice with T-cell-specific IFT20 deficiency exhibited reduced allergen-induced airway inflammation. Thus, our data suggest that the IFT20-TSG101 axis regulates AKT-mTOR signaling via SMAC formation.


Asunto(s)
Proteínas Proto-Oncogénicas c-akt , Linfocitos T , Animales , Ratones , Proteínas Portadoras/metabolismo , Antígenos CD28/metabolismo , Linfocitos T CD4-Positivos , Proteínas Proto-Oncogénicas c-akt/metabolismo , Linfocitos T/metabolismo , Serina-Treonina Quinasas TOR/metabolismo
17.
Materials (Basel) ; 16(6)2023 Mar 11.
Artículo en Inglés | MEDLINE | ID: mdl-36984141

RESUMEN

This study aimed to assess the effect of mechanical loading and heating on the cyclic fatigue and torsional fracture resistances of heat-treated nickel-titanium files after usage and autoclaving. Sixty files (One Curve) were tested for cyclic fatigue and torsional fracture resistances using customized devices. The files were divided into three groups according to the test conditions (n = 10); new (group-N), used for simulated canal shaping (group-U), and sterilized after use (group-S). For cyclic fatigue resistances, the files were freely rotated in a curved metal canal under body temperature; the time elapsed to fracture was recorded and the numbers of cycles to fracture (NCF) were calculated. For the torsional resistances, the file tip was fixed and rotated until the file fractured. The maximum torsional load and distortion angle were recorded. The toughness was calculated. Fracture fragments were examined with a scanning electron microscope. Data were analyzed using a one-way analysis of variance and Tukey's post hoc test at the significance level of 95%. Group-U showed significantly higher NCF than group-S (p < 0.05). However, there was no significant differences between groups-N and -S in the NCF (p > 0.05). Group-N showed a significantly bigger distortional angle and higher torsional toughness than groups-U and -S, but the ultimate torsional strength did not have significant difference between the groups. Under the limitation of this study, autoclave sterilization after single-usage did not improve the fracture resistance of heat-treated One Curve nickel-titanium files.

18.
J Endod ; 49(5): 567-574, 2023 May.
Artículo en Inglés | MEDLINE | ID: mdl-36965769

RESUMEN

INTRODUCTION: This study investigated the effect of shaping parameters of 2 different configurations of middle mesial canals (MMCs) on the biomechanical behavior and life span of a mandibular first molar using finite element analysis (FEA). METHODS: A mandibular molar with an independent MMC and another with a confluent MMC were scanned via micro-computed tomography, and FEA models were produced. For each tooth, an intact model and 5 experimental models were produced that differed by parameters of how the MMC was shaped: unshaped MMC, 25/.04, 25/.06, 30/.04, and 30/.06. Cyclic loading of 50 N was applied on the occlusal surface in vertical and oblique scenarios, and the number of cycles until failure (NCF) was compared with the intact models. In addition, mathematical analyses evaluated the stress distribution patterns and calculated maximum von Mises and maximum principal stresses. RESULTS: For both the independent and confluent MMC models, shaping the MMC reduced the NCF. The lifelog percentage of models was inversely proportional with radicular shaping parameters during the vertical and oblique loading scenarios. The shaping size of 30/.06 resulted in lower lifelog percentage than the cases with shaping size of 25/.04 in both of the independent and confluent MMC models. For all models, oblique loading reduced NCF more than vertical loading. CONCLUSION: Shaping the MMC should be kept as conservative as 25/.04. Also, whether the MMC is independent or confluent is a deciding factor in whether to increase the apical diameter or the root canal taper when larger shaping parameters are needed.


Asunto(s)
Cavidad Pulpar , Tratamiento del Conducto Radicular , Cavidad Pulpar/diagnóstico por imagen , Análisis de Elementos Finitos , Microtomografía por Rayos X , Diente Molar/diagnóstico por imagen , Mandíbula
19.
J Endod ; 49(1): 77-82, 2023 Jan.
Artículo en Inglés | MEDLINE | ID: mdl-36375648

RESUMEN

INTRODUCTION: This study evaluated the effect of periodic changes in rotation speed on torsional stress and screw-in force using the dedicated alternative rotation technique (ART) motion of the EQ-M (Metabiomed, Cheongju, Korea) endodontic motor. METHODS: Two ART modes of the EQ-M motor in 2 alternative techniques (ART30 and ART50) and continuous rotation were compared using ProTaper Next X2 (Dentsply Sirona, Charlotte, NC) files and simulated resin blocks (n = 12 per group). ART30 and ART50 were operated by continuous rotation of 350 rpm for 360° and then rotated at 30% increased speed from the base speed for 180° and at 50% increased speed for 180°, respectively. Before the test, the simulated resin blocks were pre-enlarged using ProTaper Gold S1 and S2 (Dentsply Sirona) and fixed on a metal stage connected to the force- and torque-measuring unit. During shaping the simulated canal in an automatic up-and-down manner, the parameters of maximum torque, sum of torque, maximum screw-in force, and maximum apical force were measured. The data were statistically analyzed using 1-way analysis of variance and the Tukey post hoc comparison test at the 95% significance level. RESULTS: The ART30 and ART50 groups showed a lower maximum torque, sum of torques, screw-in force, and apical drive force than the continuous rotation group. There was no significant difference between the ART30 and ART50 groups (P > .05). When the screw-in force increased suddenly, the torque correspondently increased. CONCLUSIONS: Under the limitations of this study, the ART mode could reduce the torsional stress and apical forces of the screw-in during instrumentation in comparison with continuous rotation.


Asunto(s)
Aleaciones Dentales , Preparación del Conducto Radicular , Titanio , Diseño de Equipo , Torque , Tornillos Óseos , Estrés Mecánico , Ensayo de Materiales
SELECCIÓN DE REFERENCIAS
DETALLE DE LA BÚSQUEDA
...